The K series waterproof push pull connector has the same insulator and contacts as the B series, but the IP degree is IP68. They have the following main features:
- Multipole types 2 to 30 contacts
- Solder, crimp, or print (straight or elbow) contacts
- Keying system («G» key standard) for connector alignment
- Multiple key options for mating correctly
- 360° screening for full EMC shielding
- High packing density for space savings
- Rugged housing for extreme working conditions
- Available customized cable assembly solution
- Front panel mount, Back panel mount & Cable mount
| Part Number | Product Photo | Description |
|---|---|---|
| INT-ZGG | ![]() | K series waterproof fixed receptacle, nut fixed, solder contacts |
| INT-ZGG | ![]() | K series waterproof fixed receptacle, nut fixed, PCB contacts |
| INT-ZEG | ![]() | K series waterproof back panel mount receptacle, nut fixed, solder contacts |
| INT-ZEG | ![]() | K series waterproof back panel mount receptacle, right angle PCB contacts |
| INT-DHG | ![]() | K series cable mount receptacle, cable collet |
| INT-DHG | ![]() | K series cable mount receptacle, nut for fitting bend r |
K Series Connectors with the Following Main Features
- Security of the push-pull latching system
- Watertight connection (IP 66~IP 68)
- Multipole types 2 to 30 contacts
- Solder, crimp or print (straight or elbow) contacts
- Keying system («G» key standard) for connector alignment
- Multiple key options to avoid cross mating of similar connectors
- 360° screening for full EMC shielding
- High packing density for space savings
- Rugged housing for extreme working condition
K series Cable Mount Waterproof Receptacle Cable Collet:













Products Categories
Iks Menu
Menu not found (id = 304)
Get A Free Quote
Technical
Technical Characteristics
Mechanical and Climatically
| Characteristics | Value | Standard |
|---|---|---|
| Endurance: | >6000 cycles | IEC60512-5 test 9a |
| Temperature range: | -40°C, +250°C | |
| Humidity: | Up to 95% at 60°C | |
| Resistance to vibrations | 10 Hz – 2000 Hz 15 g | IEC 60512-4 test 6d |
| Shock resistance | 100 g, 6 ms | IEC 60512-4 test 6c |
| Salt spray corrosion test | >144 h | IEC 60512-6 test 11f |
| Protection index (mated) | IP68 | IEC 60529 |
| Climatical category | 55/175/21 | IEC 60068-1 |
Electrical
| Characteristics | Value | Standard | |
|---|---|---|---|
| Shielding efficiency | at 10 MHZ | >95 dB | IEC 60619-1-3 |
| at 1 GHz | >80 dB | IEC 60619-1-3 | |